HOME > Air Compressor HOME> Technical Data : Installation

Air CompressorInstallation : Technical Data

Breaker | Ventilation | Drain | Tank | Piping

Ventilation

Motor output Ventilation amount (in case of air cooling) Cooling tower
(in case of water cooling)
Heat amount generated
(MJ/h)
Exhausted air amount
(m3/min)
If t = 5
(m3/min)
CT exit temperature,
if 32ºC
7.5kW 32 20 85  
11kW 47 30 125  
15kW 68
[54]
45
[85]
(80)*3
180
[145]
5t over
22kW 97
[79]
55
[105]
(80)*3
260
[210]
10t over
30kW (121)*3 (100)*3 (340)*3  
37kW 159
[130]
85
[200]
(120)*3
430
[400]
10t over
45kW (184)*3 (150)*3 (510)*3  
55kW 201
[Please ask us]
140
[Please ask us]
880
[Please ask us]
15t over
75kW 272
[Please ask us]
190
[Please ask us]
1,200
[Please ask us]
20t over
90kW       30t over
100kW       30t over
120kW       30t over
150kW       30t over

The figures in [ ] are those of ZU and ZUV.
(Please ask us or the designated service factory about the details)
*3: Applied to i-14000 IPM motor machine.