HOME > Air Compressor HOME> Technical Data : Air Discharge Volume

Air CompressorAir Discharge Volume : Technical Data

Normal | Pressure drop in direct piping | Ventilation volume | Drain volume

Various calculations

Pressure drop in direct piping

Pressure 7kgf/cm2(700kPa) a pressure descent for pipe length 100m (kgf/cm2)

A free air
m3/min
A 20 25 32 38 50 65 80 90 100 115 125 150 175 200 250
B 3/4 1 1:1/4 1:1/2 2 2:1/2 3 3:1/2 4 4:1/2 5 6 7 8 10
inside
diameter
mm
21.6 27.6 35.7 41.6 52.9 67.9 80.7 93.2 105.3 118.1 130.8 155.2 180.2 204.7 254.2
1   0.290 0.081 0.018 0.008                      
2     0.324 0.077 0.032 0.009                    
3       0.170 0.072 0.020                    
4       0.300 0.134 0.036 0.013                  
5         0.204 0.055 0.021                  
6           0.079 0.030 0.010                
7           0.108 0.041 0.013                
8           0.142 0.055 0.017                
9           0.180 0.069 0.022                
10           0.222 0.085 0.027 0.013              
12             0.112 0.039 0.018 0.009            
14             0.167 0.053 0.025 0.012            
16             0.218 0.069 0.032 0.016 0.009          
18               0.087 0.041 0.021 0.012          
20               0.107 0.051 0.025 0.014 0.008        
25               0.168 0.080 0.040 0.022 0.012        
30                 0.115 0.051 0.032 0.015        
35                 0.159 0.078 0.044 0.018        
40                   0.102 0.057 0.031 0.012      
45                   0.129 0.072 0.039 0.015      
50                   0.160 0.089 0.048 0.018 0.008    
60                     0.129 0.079 0.027 0.012    
70                       0.095 0.036 0.016 0.008  
80                       0.123 0.047 0.021 0.011  
90                         0.060 0.026 0.014  
100                         0.074 0.033 0.017  
150                             0.038 0.011
200                             0.067 0.020

Calculation Example
There are 3 units of 37kW (Z37) and 2 units of 55kW (Z55). How much should the thickness of the main pipe from the compressor room of a new factory to each factory be?
(6.1m3 / min x 3) + (9.1m3 / min x 2) = 36.5m3 / min
∴ Select 3:1/2B (90A) or more in accordance with the pressure loss table.

The selection conditions of the size of air pressure piping

Equivalency direct pipe length of a pipe belonging(m)

  Pipe diameter(B)
1/4 3/8 1/2 3/4 1 1:1/4 1:1/2 2 2:1/2 3 4 5 6 8 10 12

90°elbow
Screwing SS 0.7 0.9 1.1 1.3 1.6 2.0 2.3 2.6 2.9 3.4 4.0          
FC                   2.7 3.4          
flange SS     0.3 0.4 0.5 0.6 0.7 0.9 1.1 1.3 1.8 2.2 2.7 3.7 4.3 5.2
FC                   1.1 1.5   2.2 3.0 3.7 4.6

90°long elbow
Screwing SS 0.5 0.6 0.7 0.7 0.8 1.0 1.0 1.1 1.1 1.2 1.4          
FC                   1.0 1.1          
flange SS     0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.3 1.5 1.7 2.1 2.4 2.7
FC                   0.0 1.0   1.4 1.7 2.1 2.4

45°elbow
Screwing SS 0.1 0.2 0.2 0.3 0.4 0.5 0.7 0.8 1.0 1.2 1.7          
FC                   1.0 1.4          
flange SS     0.1 0.2 0.3. 0.4 0.4 0.5 0.6 0.8 1.1 1.4 1.7 2.4 2.7 3.3
FC                   0.6 0.9   1.4 1.9 2.5 3.0

Tee
Screwing SS 0.2 0.4 0.5 0.7 1.0 1.4 1.7 2.4 2.8 3.7 5.0          
FC                   3.0 4.2          
flange SS     0.2 0.3 0.3 0.4 0.5 0.6 0.6 0.7 0.9 1.0 1.2 1.4 1.6 1.8
FC                   0. 0.   0. 1. 1. 1.

Tee
Screwing SS 0.7 1.1 1.3 1.6 2.0 2.8 3.0 3.7 4.0 5.2 6.4          
FC                   4.2 5.2          
flange SS     0.6 0.8 1.0 1.3 1.6 2.0 2.3 2.9 3.7 4.6 5.5 7.3 9.1 10.3
FC                   2.4 3.0   4.6 6.1 7.6 9.1

180°bend
Screwing SS 0.7 0.9 1.1 1.3 1.6 2.0 2.3 2.2 2.8 3.4 4.0          
FC                   2.7 3.4          
flange SS     0.3 0.4 0.5 0.6 0.7 0.9 1.1 1.3 1.8 2.2 2.7 3.8 4.3 5.2
FC                   1.1 1.5   2.2 3.0 3.7 4.6
long
flange
SS     0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.3 1.5 1.7 2.2 2.5 2.8
FC                   0.9 .1.0   1.4 1.7 2.1 2.4

Spherical valve
Screwing SS 6.4 6.7 6.7 7.3 8.8 11.3 12.8 16.5 18.9 24.1 33.5          
FC                   19.8 26.2          
flange SS     11.6 12.2 13.7 16.5 18.0 21.3 23.5 28.6 36.5 45.6 57.8 79.1 94.5 11.9
FC                   23.5 30.2   45.7 64.0 82.2 10.0

Gate valve
Screwing SS 0.1 0.1 0.2 0.2 0.3 0.3 0.4 0.5 0.5 0.6 0.8          
FC                   0.5 0.6          
flange SS               0.8 0.8 0.9 0.9 1.0 1.0 1.0 1.0 1.0
FC                   0.7 0.7   0.8 0.8 0.9 0.9

Angle valve
Screwing SS 3.9 4.6 4.6 4.6 5.2 5.5 5.5 .5.5 5.5 5.5 5.5          
FC                   4.6 4.6          
flange SS     4.6 4.6 5.2 5.5 5.5 6.4 6.7 8.5 11.6 15.2 19.2 27.4 36.6 42.6
FC                   7.0 9.4   15.8 22.6 29.9 36.5

Swing stop valve
Screwing SS 2.2 2.2 2.4 2.7 3.4 4.0 4.6 5.8 6.7 8.2 11.6          
FC                   6.7 9.5          
flange SS     1.2 1.6 2.2 3.1 3.7 5.2 6.4 8.2 11.6 15.2 19.2 27.4 36.6 42.7
FC                   6.7 9.5   15.8 22.6 29.9 36.5
Coupling and unit Screwing SS 0.04 0.06 0.06 0.07 0.09 0.1 0.1 0.1 0.1 0.1 0.2          
FC                   0.1 0.3